Zeta Analogue Addressable 2 Loop Fire Alarm Panel

Art.Nr.:
GCT10429

Call for Price

01847213868

Zeta  Analogue Addressable  2 Loop  Fire Alarm Panel 

Two loop addressable fire alarm panel
Complies fully to EN54 parts 2 & 4
User definable zones
Option for zonal or common alarm operation
Options for I/O operation
Alarm verification (help prevent false alarms)
User selectable languages
2,048 event log (fire & fault)

Zeta  Analogue Addressable  2 Loop  Fire Alarm Panel 

The Zeta Analogue Addressable 2-Loop Fire Alarm Panel is a high-performance fire safety control panel designed for medium to large scale commercial, institutional and industrial installations. With full analogue-addressable capability, this panel supports two detection loops, enabling integration of hundreds of addressable detectors, call‐points and sounders in a flexible, intelligent fire alarm system.

Engineered with advanced programming, built-in event logging, multi-zone management, short-circuit isolation and emergency outputs, the panel offers professional fire detection, monitoring and control in one robust enclosure. For Bangladesh installations requiring reliable fire alarm performance, the Zeta 2-Loop panel delivers the features, scalability and compliance suitable for offices, factories, schools, hotels and shopping complexes.

Zonal Addressing

All devices are assigned to a specific zone based on their address. This removes a programming step and helps to streamline the commissioning process. The following table outlines which addresses fall in which zones.

Alarm Verification

To help prevent false alarm causing a full evacuation, any smoke detector can be set to alarm verification mode with a time delay of between 30 seconds and 4 minutes. Should any of these detectors go into alarm then only the detector’s LEDs and sound/flasher base

(if connected) will activate. Should the alarm not be cleared with this time delay then a common alarm will occur.

Technical Specifications: 

 Model

 SP-252

 Part No.

 37-177

 Supply Voltage

 230V AC +/- 10%

 System Voltage

 24V DC (Nominal)

 Number of Loops

 2

 Loop Capacity

 126 Devices per Loop (Total 252)

 Number of Zones

 8

 Sounder Output

 Addressable Sounders Only

 Fault Output

 28V Repeat Output to Drive Relay (Normally Energized)  

 Fire Output

 28V Repeat Output to Drive Relay

 Operating Temperature

 -0°C to 50°C

 Enclosure Size

 375mm x 335mm x 125mm

 

Write Your Own Review
You're reviewing:Zeta Analogue Addressable 2 Loop Fire Alarm Panel
Your Rating