Top Fire Alarm Bell & Siren Price in Bangladesh

Best Fire Alarm Bell & Siren Price in Bangladesh. October , 2025 Latest Price
Conventional Fire Alarm Bell Call for Price

What is Fire Alarm Bells?

A fire alarm bell is one of the most fundamental yet critical components in any fire protection system, it alerts occupants quickly, enabling evacuation and helping to save lives. In this guide, you’ll learn everything from how fire alarm bells work, key specifications and standards, to selection, installation and maintenance best practices. By the end, you’ll be well-equipped to choose the right fire alarm bell for your needs and trust the product you purchase.

Why Fire Alarm Bells Are Still Relevant Today

Although many modern systems emphasize horns, electronic sounders and voice alerts, traditional bells have enduring value. Bells produce a distinct, recognizable ringing sound that is hard to confuse with other alarms. In many regions, building codes and fire safety regulations still permit or even require bells in retrofit or existing fire alarm systems. According to NFPA 72 and associated standards, bells remain valid “notification appliances,” especially in older systems or zones that already use bells.

Additionally, bells tend to be simpler, lower cost and highly reliable over decades with fewer moving parts and less dependence on complex electronics. This makes them a strong choice for many industrial, educational and residential setups.

How Does a Fire Alarm Bell Work?

A fire alarm bell typically comprises the following:

  • Bell dome and mounting base: Usually cast aluminum or steel, painted red (for fire safety visibility).

  • Actuation mechanism: In an electric bell, a small electromagnetic hammer repeatedly strikes the bell dome when energized. In a motorised bell, a rotating mechanism strikes or vibrates the bell. Some bells are manual rotary, operated by a hand crank in special (often remote or temporary) environments.

  • Power / input terminals: For wiring to a control panel, zone circuit, or auxiliary device.

  • Sound output: Measured in decibels (dB), typically at 1 meter or as indicated by the manufacturer.

  • Voltage specification: Many bells run on 24 VDC, others run on AC systems (e.g. 110/120 VAC) or specialized voltages depending on regional norms.

When the control panel triggers the bell (via a relayed circuit, manual pull station, or sprinkler water flow switch), the mechanism is energized and sound is generated. In systems where bells are tied to sprinkler flows, a water motor gong variant may automatically ring when water flows in the pipe system.

Key Specifications to Consider

When selecting a fire alarm bell, scrutinize the following attributes carefully. These often differentiate reliable, code-compliant bells from inferior ones.

 Specification

 Why It Matters

 Typical / Recommended Values

 Voltage / Current

 Must match your system ( 24VDC, 110VAC). Wrong voltage leads to misoperation or damage.

 24 VDC is common; AC variants exist. 

 Sound output (dB)

 Must be loud enough to alert even with ambient noise.

 80 dB(A) or higher is common. Some bells reach 95 dB.

 Bell size / diameter

 Influences sound projection and audibility.

 6-inch and 8-inch versions are standard. 

 Ingress / Environmental Rating

 For outdoor or harsh locations, you’ll need a bell rated for weather, dust, humidity, etc.

 Look for IP-rated or outdoor “weatherproof” models.

 Mounting provisions

 Bells should come with mounting holes or brackets.

 Pre-drilled holes for easy wall/ceiling mounting. 

 Certification / Listing

 Ensures safety, reliability, and code compliance

 UL listing for audible signaling devices (UL 464), EN54 series in Europe, etc.

 Compatibility with fire alarm control panel

 The bell’s circuit and load must be supported by the panel.

 Ensure current draw is within panel zone output limits.

By balancing these specifications against your building layout and code requirements, you’ll choose a bell that is safe, effective, and compliant.

Types of Fire Alarm Bell Systems

Understanding how bells integrate into broader fire alarm architectures is crucial. Here are common system types and considerations:

1. Conventional / Classic Bell Systems

All detectors, pull stations, and bells are wired in zones to a central fire alarm control panel (FACP). When any device in a zone triggers, all bells in that zone ring. This is simple, cost-effective, and widely used in many installations. 

2. Addressable / Intelligent Systems

Here, each detection device (smoke, heat, pull station) has a unique “address” programmable in the FACP. When triggered, the panel knows exactly which device initiated the alarm. Bells remain part of the notification circuit, but the system is smarter in diagnostics and fault isolation. 

3. Wireless / Radio-Based Systems

In newer systems, bells and detectors communicate using secure radio frequencies, eliminating many wiring needs. Wireless bells follow standard protocols and still must conform to local fire codes. They’re useful in retrofits or areas where running wires is difficult.

Be cautious: mixing wildly different output devices (bells, horns, electronic sounders) in the same system can confuse occupants. Many codes and guidelines discourage mixing alarm types unless the sound signature is consistent.

Standards & Regulations

To ensure safety and legal compliance, your fire alarm bells must meet relevant codes. Here are some key standards:

NFPA 72 (U.S. National Fire Alarm & Signaling Code)

This is the foundational code that governs design, installation, performance, inspection, testing, and maintenance of fire alarm systems, including notification devices like bells.

NFPA 72 requires that all notification appliances (bells, horns, strobes) be listed for the purpose they are used, and installed per manufacturer instructions.

UL 464 (U.S. Standard for Audible Signaling Devices)

UL 464 covers requirements for bells, horns, and sounders. A bell with UL 464 listing is tested to ensure reliability, proper operation, and safety.

NFPA / ADA & Disability Considerations

In many jurisdictions, audible alarms must be accompanied by visual (strobe) signals to alert persons with hearing impairment. NFPA 72 and ADA (Americans with Disabilities Act) are aligned in some contexts.

Local Codes & Fire Authority Mandates

Local building codes may adopt versions of national standards or impose region-specific rules (e.g., mounting height, external bell requirements, outdoor zones). Always check with your local fire marshal or authority having jurisdiction (AHJ).

OSHA & Workplace Alarm Requirements

For occupational settings, OSHA rules may affect how alarms are deployed for evacuation or worker warning.

By aligning with these standards, you not only protect lives you also reduce liability and increase trust with your customers.

Mounting & Installation Best Practices

Proper mounting and placement are essential for effectiveness. A poorly placed bell may go unheard, defeating its purpose.

Height & Positioning

  • NFPA 72 generally recommends that wall-mounted bells be installed so their tops are at least 90 inches (2.29 m) above finished floors, with at least 6 inches clearance from ceiling.

  • Exceptions are allowed if the sound output requirement is still met.

  • Avoid installing bells too close to structural steel or noise-generating machinery unless sound propagation is adequately accounted for.

Audibility & Overlap

  • Place bells such that every part of the protected space receives the required sound level (often 15 dB above ambient or a minimum threshold) as outlined in NFPA.

  • Overlap zones where possible to ensure no “dead spots.”

  • Avoid obstructions like cabinets or piping in front of bells.

Wiring Considerations

  • Use properly gauged fire-rated cables.

  • Ensure polarity (for DC) is correct where applicable (some bells are nonpolar).

  • Maintaining proper current capacity control panels often limits how many bells can be powered on a zone.

  • Use separate circuits for emergency wiring if required by local code.

Environmental Protections

  • For outdoor / exposed locations, use weatherproof or ingress-protected bells.

  • Consider corrosion-resistant materials ( powder coat, stainless hardware).

  • If installed near ventilation, machinery, or noise zones, compensate with higher output devices.

Testing During Installation

  • After mounting, do a functional test to verify the bell rings clearly.

  • Confirm audibility at farthest corners of rooms.

  • Document test results and date of installation.

Maintenance, Testing & Troubleshooting

A fire alarm bell is only effective if it works when needed. Proper maintenance is non-negotiable.

Routine Testing

  • Monthly or quarterly visual inspections: Check bell mounting, connections, visible damage, paint, presence of obstructions.

  • Semi-annually or annually, perform functional tests by activating the circuit and hearing the bell ring.

  • Verify current draw and voltage under load matches specifications (for signs of aging or wiring degradation).

  • Maintain a log of all tests, repairs, and inspections (essential for audits or insurance).

Cleaning & Servicing

  • Remove dust, debris, insects that may clog the bell or dampen sound.

  • Repaint or touch up corrosion spots (but avoid muffling the dome).

  • Replace aging wiring, connectors, or mounting hardware as needed.

Troubleshooting Common Issues

 Problem

 Possible Cause

 Solution

 Bell doesn’t ring

 Broken connection, no power, wrong voltage

 Check wiring, panel output, voltage, fuse/trip

 Weak / muffled ringing

 Accumulated dust, misalignment, damage

 Clean bell, realign parts, inspect dome/hammer

 Intermittent operation

 Loose wiring, loose mounting, aging c  omponents

 Tighten connections, replace cables, service bell

 Too loud / distortions

 Extra vibration, resonance issues

 Install vibration isolators or spacers properly

If bells are part of an integrated fire alarm system, any malfunction should also prompt your fire alarm technician to inspect the control panel and wiring continuity.

Choosing the Right Fire Alarm Bell

When listing fire alarm bells in your online store, you’ll want to provide clarity, credibility, and ease of decision for your customers. Here’s how to structure the product category and descriptions for maximum trust and SEO visibility:

Product Titles & SEO Keywords

  • Use clear titles with your primary keyword: e.g. “6-inch 24VDC Fire Alarm Bell (UL Listed)”

  • Include long-tail keywords: “outdoor weatherproof fire alarm bell 95 dB”, “manual rotary fire alarm bell 60 dB”

  • Add secondary / semantic keywords in description: “alarm bell”, “notification appliance”, “signal bell”, “fire safety bell”

Product Descriptions

  • First 1–2 sentences should reaffirm buyer intent: “This fire alarm bell is ideal for …”

  • Highlight specs: voltage, sound output, dimensions, mounting features, certifications.

  • Explain use-case: indoor/outdoor, retrofits, schools, factories, etc.

  • Mention standards and compliance (UL, EN, NFPA 72).

  • Include bullet points for quick scan:

    • 24 VDC operation, 38 mA current draw

    • Output: 95 dB(A) @ 1 m

    • Aluminum casing, IP rating

    • Pre-drilled mounting holes

    • UL 464 / EN54 listed

Comparison Tables & Buying Guides

Include a comparative table (6″ vs 8″, AC vs DC, indoor vs outdoor) to help customers choose. Also, embed a buyer’s guide (like this article) or link to it for added authority.

Rich Media & Trust Signals

  • Show clear, high-resolution images of bells from multiple angles (dome, back, terminals).

  • Provide downloadable datasheets / spec sheets.

  • Show certification logos (UL, CE, EN).

  • Include customer reviews or case studies.

  • Offer installation diagrams or video demos.

Use Cases & Applications

Fire alarm bells are used across a wide range of settings. Understanding typical applications helps customers envision the right use.

  1. Commercial Buildings / Offices
    Bells can be part of conventional or addressable fire alarm systems, notifying building occupants throughout zones.

  2. Educational Institutions / Schools
    Many schools prefer the ringing tone of bells for familiarity, class change, or fire drill signaling.

  3. Industrial Facilities / Warehouses
    In noisy environments, louder bells with overlapping zones ensure everyone hears the alarm.

  4. Residential / Multi-Unit Dwellings
    In smaller buildings or apartment blocks, bells can be integrated into shared fire systems in common corridors.

  5. Retrofits & Renovations
    In older buildings, existing bell circuits are often reused or upgraded for easier integration.

  6. Temporary or Remote Sites
    Manual rotary bells are ideal for temporary structures, construction sites, camps, or remote buildings without stable power.

By displaying these use-case examples in your eCommerce listing, you help customers quickly gauge whether your bells are suitable for their scenario.

Summary & Final Recommendations

  • A fire alarm bell remains a vital, cost-effective notification appliance, especially in many existing or retrofit fire alarm systems.

  • Focus on matching voltage, sound output, mounting type, environmental rating, and certification when choosing a bell.

  • Follow relevant codes (like NFPA 72, UL 464) and local fire authority rules to ensure compliance.

  • Install bells properly (height, overlap zones, unobstructed) and maintain/test regularly to ensure functionality.

  • In your eCommerce category, use SEO best practices: clear titles, long-tail keywords, buyer guides, FAQs, product specs, reviews, and internal linking.

  • Build topical authority by offering high-quality informational content (like this guide), multimedia, and product comparisons.